Journal of Bionic Engineering ›› 2024, Vol. 21 ›› Issue (3): 1305-1320.doi: 10.1007/s42235-024-00500-y

• • 上一篇    下一篇

Design and Verification of Parallel Hip Exoskeleton Considering Output Torque Anisotropy

Jilong Xu1,2 · Yunzhan Niu3 · Fucai Liu1,2   

  1. 1.Engineering Research Center of the Ministry of Education for Intelligent Control System and Intelligent Equipment, Yanshan University, Qinhuangdao 066004, China  2. Key Laboratory of Industrial Computer Control Engineering of Heibei Province, Yanshan University, Qinhuangdao 066004, China 3.College of Mechanical Engineering, Yanshan University, Qinhuangdao 066004, China
  • 出版日期:2024-05-20 发布日期:2024-06-08
  • 通讯作者: Fucai Liu, Jilong Xu, Yunzhan Niu E-mail:lfc@ysu.edu.cn;1010615915@qq.com;1046486208@qq.com
  • 作者简介:Jilong Xu1,2 · Yunzhan Niu3 · Fucai Liu1,2

Design and Verification of Parallel Hip Exoskeleton Considering Output Torque Anisotropy

Jilong Xu1,2 · Yunzhan Niu3 · Fucai Liu1,2   

  1. 1.Engineering Research Center of the Ministry of Education for Intelligent Control System and Intelligent Equipment, Yanshan University, Qinhuangdao 066004, China  2. Key Laboratory of Industrial Computer Control Engineering of Heibei Province, Yanshan University, Qinhuangdao 066004, China 3.College of Mechanical Engineering, Yanshan University, Qinhuangdao 066004, China
  • Online:2024-05-20 Published:2024-06-08
  • Contact: Fucai Liu, Jilong Xu, Yunzhan Niu E-mail:lfc@ysu.edu.cn;1010615915@qq.com;1046486208@qq.com
  • About author:Jilong Xu1,2 · Yunzhan Niu3 · Fucai Liu1,2

摘要: In rehabilitation training, it is crucial to consider the compatibility between exoskeletons and human legs in motion. However, most exoskeletons today adopt an anthropomorphic serial structure, which results in rotational centers that are not precisely aligned with the center of the hip joint. To address this issue, we introduce a novel exoskeleton called the Parallel Hip Exoskeleton (PH-Exo) in this paper. PH-Exo is meticulously designed based on the anisotropic law of output torque. Considering the friction of the drive components, a dynamic model of the human–machine complex is established. Simulation analysis demonstrates that PH-Exo not only exhibits outstanding torque performance but also achieves high controllability in both flexion/extension and adduction/abduction directions. Additionally, a robust controller is designed to address model uncertainty, friction, and external interference. Wearing experiments indicate that under the control of the robust controller, each motor achieves excellent tracking performance.

关键词: Hip exoskeleton , · Parallel mechanism , · Misalignment , · Anisotropy , · Output torque

Abstract: In rehabilitation training, it is crucial to consider the compatibility between exoskeletons and human legs in motion. However, most exoskeletons today adopt an anthropomorphic serial structure, which results in rotational centers that are not precisely aligned with the center of the hip joint. To address this issue, we introduce a novel exoskeleton called the Parallel Hip Exoskeleton (PH-Exo) in this paper. PH-Exo is meticulously designed based on the anisotropic law of output torque. Considering the friction of the drive components, a dynamic model of the human–machine complex is established. Simulation analysis demonstrates that PH-Exo not only exhibits outstanding torque performance but also achieves high controllability in both flexion/extension and adduction/abduction directions. Additionally, a robust controller is designed to address model uncertainty, friction, and external interference. Wearing experiments indicate that under the control of the robust controller, each motor achieves excellent tracking performance.

Key words: Hip exoskeleton , · Parallel mechanism , · Misalignment , · Anisotropy , · Output torque