Journal of Bionic Engineering ›› 2024, Vol. 21 ›› Issue (4): 1801-1816.doi: 10.1007/s42235-024-00518-2

• • 上一篇    下一篇

Bioinspired Scraper‑File Type Frequency‑Doubling Ultrasonic Exciter

Wenshuai Wu1,2; Mingshuo Zhang1,2; Zeming Li1,2; Guang Yao3 ; Xinggang Jiang1,2; Deyuan Zhang1,2   

  1. 1 School of Mechanical Engineering and Automation, Beihang University, Beijing 100191, China  2 Institute of Bionic and Micro-Nano Systems, Beihang University, Beijing 100191, China  3 Guangdong Provincial Key Laboratory of Minimally Invasive Surgical Instruments and Manufacturing Technology, Guangdong University of Technology, Guangzhou 510006, China
  • 出版日期:2024-07-15 发布日期:2024-09-01
  • 通讯作者: Deyuan Zhang E-mail:zhangdy@buaa.edu.cn
  • 作者简介:Wenshuai Wu1,2; Mingshuo Zhang1,2; Zeming Li1,2; Guang Yao3 ; Xinggang Jiang1,2; Deyuan Zhang1,2

Bioinspired Scraper‑File Type Frequency‑Doubling Ultrasonic Exciter

Wenshuai Wu1,2; Mingshuo Zhang1,2; Zeming Li1,2; Guang Yao3 ; Xinggang Jiang1,2; Deyuan Zhang1,2   

  1. 1 School of Mechanical Engineering and Automation, Beihang University, Beijing 100191, China  2 Institute of Bionic and Micro-Nano Systems, Beihang University, Beijing 100191, China  3 Guangdong Provincial Key Laboratory of Minimally Invasive Surgical Instruments and Manufacturing Technology, Guangdong University of Technology, Guangzhou 510006, China
  • Online:2024-07-15 Published:2024-09-01
  • Contact: Deyuan Zhang E-mail:zhangdy@buaa.edu.cn
  • About author:Wenshuai Wu1,2; Mingshuo Zhang1,2; Zeming Li1,2; Guang Yao3 ; Xinggang Jiang1,2; Deyuan Zhang1,2

摘要: In the natural world, leaf-cutting ants cause vibrations through their mutual scraping of fle-scraper organs. In this study, we designed a Biomimetic Ultrasonic Exciter (BUE) that imitates leaf-cutting ants. The operating characteristics of the BUE were studied through experimental testing and fnite element simulations. The results showed that the BUE could generate stable ultrasonic vibrations, and that the excitation frequency only needed to be half the Output Frequency (OF). This frequency-doubling phenomenon was conducive to achieving BUE miniaturization. To further explore the phenomenon of frequency-doubling vibration output, this study designed scrapers of fve diferent sizes, conducted excitation and frst-order natural frequency measurement tests, and the corresponding fnite element simulations. It was found that each scraper could operate in frequency-doubling mode, but the operating frequency and natural mode frequencies did not correspond with one another. To further explicate experimental and simulation results, a two-degrees-of-freedom vibration model was developed. It was evident that the contact relationship between the dentate disc and scraper introduced strong nonlinear factors into the system, accounting for the frequency-doubling phenomenon and the diference between the BUE’s operating and mode frequencies. The BUE could be expected to facilitate the production of high-power micro-ultrasonic generators and has potential application value in the felds of mechanical processing, industrial production, and medical health.

关键词: Leaf-cutting ants , · Power ultrasound , · Nonlinear vibration , · Ultrasonic scalpel , · Micro vibrator

Abstract: In the natural world, leaf-cutting ants cause vibrations through their mutual scraping of fle-scraper organs. In this study, we designed a Biomimetic Ultrasonic Exciter (BUE) that imitates leaf-cutting ants. The operating characteristics of the BUE were studied through experimental testing and fnite element simulations. The results showed that the BUE could generate stable ultrasonic vibrations, and that the excitation frequency only needed to be half the Output Frequency (OF). This frequency-doubling phenomenon was conducive to achieving BUE miniaturization. To further explore the phenomenon of frequency-doubling vibration output, this study designed scrapers of fve diferent sizes, conducted excitation and frst-order natural frequency measurement tests, and the corresponding fnite element simulations. It was found that each scraper could operate in frequency-doubling mode, but the operating frequency and natural mode frequencies did not correspond with one another. To further explicate experimental and simulation results, a two-degrees-of-freedom vibration model was developed. It was evident that the contact relationship between the dentate disc and scraper introduced strong nonlinear factors into the system, accounting for the frequency-doubling phenomenon and the diference between the BUE’s operating and mode frequencies. The BUE could be expected to facilitate the production of high-power micro-ultrasonic generators and has potential application value in the felds of mechanical processing, industrial production, and medical health.

Key words: Leaf-cutting ants , · Power ultrasound , · Nonlinear vibration , · Ultrasonic scalpel , · Micro vibrator